Dialysis Machine

Dialysis Machine HDM-1000A
Dialysis Machine HDM-1000A
Venous pressure -700 ~+800 mmHg, Accuracy ± 10 mmHg
Arterial pressure +800mmHg, Accuracy±10mmHg
Trans membrane pressure -700 mmHg ~ +800 mmHg, Accuracy±10 mmHg
Blood pump 15 ml/min ~ 340 ml/min (D 6 mm)  
     20 ml/min ~ 460 ml/min (D 8mm)
Heparin pump 0 ml/h ~ 10 ml/h (±5 %)  
Precision 0.1 ml/h
Blood flow range 0 ml/min ~ 700 ml/min
Dialysate flow range 0 ml/min ~ ( 300/500/800 ) ml/min (Adjustable)
Substitution Fluid Flow 0 ~ 25 l/h
Dialysate temperature 30 ? ~ 41 ?, Accuracy ± 0.1?
Conductivity 10 ms/cm ~ 20 ms/cm Accuracy ± 0.1 ms/cm
Air detector Detecting = 0.02 mL/single bubble
Flow scope UF flow scope: 0 ~ 1800 ml/h (±30 ml/h )
ISO UF flow scope: 0 ~ 2000 ml/h (±30 ml/h)
Blood Leak detector Detecting blood leak = 0.35 ml/min (HCT 32%)
Hot rinse = 85?
Disinfection Decalcification: Rinse, citric acid
Thermal disinfection:Hot water or citric acid
Chemical disinfection: sodium hypochlorite or peracetic acid
Water supply Pressure range: 0 bar ~ 8 bar
Temperature range: 0 ? ~ 35 ?
Connected load = 2000 VA
Power supply AC 220 V, 50 Hz ~ 60 Hz
Dimension 850 × 840 × 1660 mm
Weight 140 kgs
View Product Catalog
Dialysis Machine HDM-1000C
Dialysis Machine HDM-1000C
Venous pressure 700 mmHg ~ 800 mmHg, Accuracy ± 5 mmHg
Arterial pressure 700 mmHg ~+800 mmHg, Accuracy ±5 mmHg
Trans membrane pressure 700 mmHg ~ 800 mmHg, Accuracy ±5 mmHg
Heparin pump Bolus: 0 ml/time ~ 10 ml/time
Blood flow range 0 ml/min ~ 700 ml/min
Dialysate flow range 0 ml/min ~ ( 300/ 500 / 1000 ) ml/min (Adjustable)
Dialysate temperature 30? ~ 41?, Accuracy ± 0.5?
Conductivity 0 ~ 25 ms/cm, Accuracy ± 0.1 ms/cm
Air detector Detecting = 0.02 mL/single bubble
Flow scope UF rate : 0 ~ 6000 ml/h
Accuracy: ± 30ml/h or ±1%
Blood Leak detector = 0.35 ml/min (HCT 32 %)
Hot rinse = 93?
Disinfection Decalcifiction :Rinse,Citric acid or glacial acetic acid
Chemical disinfection:Sodium hypochlorite or peracetic acid 
Thermal disinfection: Hot water or citric acid
Water supply Pressure range: 0 bar ~ 8 bar
Temperature range: 0 bar ~ 35 bar
Water flow: = 0.3 L/min
Power supply AC 220 V / 110 V, 50 Hz / 60 Hz
Dimension 1450 × 550 × 460 mm
Weight 60 kgs
View Product Catalog
Dialysis Machine HDM-1000B
Dialysis Machine HDM-1000B
Venous pressure -50 mmHg ~ +300 mmHg  (± 10 mmHg)
Arterial pressure -300 mmHg ~ +300 mmHg (± 10 mmHg)
Trans membrane pressure -100 mmHg ~ +600 mmHg   (±20 mmHg)
Heparin pump 0 ml/h ~ 10 ml/h, Accuracy ± 0.1 ml/h
Dialysate flow range 300 ml/min ~ 800 ml/min (+10%) 
300 ml/min ~ 800 ml/min (-5%)
Conductivity 13 ms/cm ~ 15.5 ms/cm   (± 0.1 mS/cm)
Blood Leak detector Over 1ml blood per liter dialysate (Flow: 500 ml/min)
Hot rinse = 85?
Disinfection Chemical disinfection (citric acid, peracetic acid and oxalic acid)
Power supply AC 220 V/ 110 V, 50 Hz / 60 Hz, 1500 W
Dimension 370 × 340 × 1570 mm
Weight 100 kgs
View Product Catalog
Dialysis Machine HDM-1000D
Dialysis Machine HDM-1000D
Venous pressure -50 mmHg ~ 300 mmHg
Arterial pressure -150 mmHg ~ 200 mmHg
Blood pump 10 ml/min ~ 340 ml/min (D 6 mm)
20 ml/min ~ 460 ml/min (D 8 mm)
Heparin pump 0.5 ml/h ~ 10 ml/h (±5 %)
Precision ± 10 %
Water supply Water tank temperature : 36 ? ~ 42 ?
Power supply AC 220 V ± 10 %
Dimension 370 × 280 × 400mm
Weight 18 kgs
View Product Catalog
Product Category
Dialysis Machine
Adult Weighing Scale
Cardiotocography Machine
Continuous Passive Motion Unit
CPAP-BiPAP
ECG Machine
Examination Light
Fetal Doppler
Infusion Pump
Isolation Clothing
Laryngoscope
Medical Trolleys
Nebulizer
Oxygen Therapy
Patient Transfer Chair
Rehabilitation Table
Suction machine
Surgical Cautery (ESU)
Thermometer
Traction System
Transcranial Doppler
Vascular Doppler
Ventilator
Wound Care
X-ray System Utilities